Absorbance Specifications Light Source Xenon flash lamp Detector Photodiode Wavelength Selection Monochromator Wavelength Range 200 to 999 nm, in 1 nm increments Wavelength Bandwidth �� 5 nm Wavelength Accuracy � 2 nm Wavelength Precision � 0.2 nm (standard deviation) Dynamic Range 0 to 4.0 OD Photometric Resolution 0.0001 OD (under Gen5 control) Pathlength Correction Yes (under Gen5 control) Photometric Accuracy <1% at 2.0 OD <3% at 2.5 OD Photometric Linearity < 1% from 0 to 2.5 OD Photometric Repeatability < 0.5% at 2.0 OD Stray Light 0.03% at 230 nm Reading Speed (Kinetic) 96 wells: 12 seconds 384 wells: 23 seconds Fluorescence Specifications Light Source Halogen Detector PMT Wavelength Selection Bandpass filters Wavelength Range 320 to 700 nm (low noise PMT) 320 to 850 nm (red-shifted PMT Dynamic Range > 6 decades Sensitivity Fluorescein 2 pM Reading Speed (Kinetic) 96 wells: 24 seconds 384 wells: 76 seconds Luminescence Specifications Dynamic Range < 6 decades Sensitivity 10 amol ATP General Specifications Microplate Formats 6, 12, 24, 48, 96, 384 wells Read Methods End point, kinetic, area scanning, absorbance spectral scanning (under Gen5 control) Plate Shaking Linear, orbital, double-orbital Read Time 96 wells: Abs 18 sec., Fl 17 sec., Lumi 120 sec. 384 wells: Abs 49 sec., Fl 48 sec., Lumi 420 sec. Dimensions (H x W x D) 12 x 15 x 15 in. (30.5 x 38.1 x 38.1 cm) Weight 27 lb. (12.3 kg.) Electrical Requirements 100-240V, 50/60Hz
Add To Cart
Absorbance Specifications Light Source Xenon flash lamp Detector Photodiode Wavelength Selection Monochromator Wavelength Range 200 to 999 nm, in 1 nm increments Wavelength Bandwidth �� 5 nm Wavelength Accuracy � 2 nm Wavelength Precision � 0.2 nm (standard deviation) Dynamic Range 0 to 4.0 OD Photometric Resolution 0.0001 OD (under Gen5 control) Pathlength Correction Yes (under Gen5 control) Photometric Accuracy <1% at 2.0 OD <3% at 2.5 OD Photometric Linearity < 1% from 0 to 2.5 OD Photometric Repeatability < 0.5% at 2.0 OD Stray Light 0.03% at 230 nm Reading Speed (Kinetic) 96 wells: 12 seconds 384 wells: 23 seconds Fluorescence Specifications Light Source Halogen Detector PMT Wavelength Selection Bandpass filters Wavelength Range 320 to 700 nm (low noise PMT) 320 to 850 nm (red-shifted PMT Dynamic Range > 6 decades Sensitivity Fluorescein 2 pM Reading Speed (Kinetic) 96 wells: 24 seconds 384 wells: 76 seconds Luminescence Specifications Dynamic Range < 6 decades Sensitivity 10 amol ATP General Specifications Microplate Formats 6, 12, 24, 48, 96, 384 wells Read Methods End point, kinetic, area scanning, absorbance spectral scanning (under Gen5 control) Plate Shaking Linear, orbital, double-orbital Read Time 96 wells: Abs 18 sec., Fl 17 sec., Lumi 120 sec. 384 wells: Abs 49 sec., Fl 48 sec., Lumi 420 sec. Dimensions (H x W x D) 12 x 15 x 15 in. (30.5 x 38.1 x 38.1 cm) Weight 27 lb. (12.3 kg.) Electrical Requirements 100-240V, 50/60Hz
Absorbance Specifications Light Source Xenon flash lamp Detector Photodiode Wavelength Selection Monochromator Wavelength Range 200 to 999 nm, in 1 nm increments Wavelength Bandwidth �� 5 nm Wavelength Accuracy � 2 nm Wavelength Precision � 0.2 nm (standard deviation) Dynamic Range 0 to 4.0 OD Photometric Resolution 0.0001 OD (under Gen5 control) Pathlength Correction Yes (under Gen5 control) Photometric Accuracy <1% at 2.0 OD <3% at 2.5 OD Photometric Linearity < 1% from 0 to 2.5 OD Photometric Repeatability < 0.5% at 2.0 OD Stray Light 0.03% at 230 nm Reading Speed (Kinetic) 96 wells: 12 seconds 384 wells: 23 seconds Fluorescence Specifications Light Source Halogen Detector PMT Wavelength Selection Bandpass filters Wavelength Range 320 to 700 nm (low noise PMT) 320 to 850 nm (red-shifted PMT Dynamic Range > 6 decades Sensitivity Fluorescein 2 pM Reading Speed (Kinetic) 96 wells: 24 seconds 384 wells: 76 seconds Luminescence Specifications Dynamic Range < 6 decades Sensitivity 10 amol ATP General Specifications Microplate Formats 6, 12, 24, 48, 96, 384 wells Read Methods End point, kinetic, area scanning, absorbance spectral scanning (under Gen5 control) Plate Shaking Linear, orbital, double-orbital Read Time 96 wells: Abs 18 sec., Fl 17 sec., Lumi 120 sec. 384 wells: Abs 49 sec., Fl 48 sec., Lumi 420 sec. Dimensions (H x W x D) 12 x 15 x 15 in. (30.5 x 38.1 x 38.1 cm) Weight 27 lb. (12.3 kg.) Electrical Requirements 100-240V, 50/60Hz